DEGRADASI SENYAWA PARAQUAT DALAM PESTISIDA GRAMOXONE® SECARA SONOZOLISIS DENGAN PENAMBAHAN TiO2-ANATASE

Neila Yenni, Safni Safni, Hamzar Suyani

Abstract

 

ABSTRACT

 

Degradation of Paraquat compound in Gramoxone pesticide had been done by sonolysis, ozonolysis, and sonozolysis. Sonolysis methods were performed using an ultrasound VC-1, ozonolysis using a bio-ozone space age sterilizer, and sonozolysis by combining sonolysis and ozonolysis methods. The optimum condition for degradation of 4 mg/L paraquat by sonolysis was found at temperature 40±1°C. Percentage of degradation at optimum condition was 22.80% with 90 minutes treatment. Whereas, with using ozonolysis method percentage of degradation of paraquat 4 mg/L was 50.39% with 60 minutes treatment. The combination of sonolysis and ozonolysis method simultaneously, these so-called sonozolysis, for degradation of the same compound, extend the percentage of degradation to 45.87% with only 30 minutes treatment.

 

Keywords: Paraquat, Sonolisis, Ozonolisis